Water is the lifeline of any industry.

In every industry, water is used in one form or other. Water is mainly used as a cooling medium in industries for equipments like heat exchangers, compressors, radiators, chillers, spot welding guns, diesel generator sets, furnaces, condensors, etc. As we all know untreated water can cause harm to the equipments and waterlines as it contains impurities like dissolved, suspended solids and biological micro-organisms. Due to these impurities, it causes problem like scaling, corrosion, algae and fungi deposits.

The main purpose of treating cooling water is to overcome the above said problems, which otherwise, leads to harmful effects like loss of heat transfer, puncturing of waterlines, pitting, irregular flow of water, reduced efficiency of cooling system, breakdown and finally, lower life of the equipment.

Antiscalant : MAX – 100

Scales in the cooling system are formed due to the salts like bi-carbonates and carbonates of calcium and magnesium which are present in water. As the temperature of the water rises, the bicarbonates decomposes to carbonates which in turn precipitates on metallic surfaces of cooling systems as scales. Silica, magnesium alkalinities, calcium sulphates, dissolved solids, rate of heat transfer and PH of the water, are the other parameters which accelerates the scale formation.

In addition to the above said parameters corrosion is also a major problem. The metals suffer corrosion when it comes in contact with water due to oxidation. The factors which results in corrosion are dissolved oxygen, free carbon dioxide content, PH factor etc., MAX - 100 is a strong formulation which inhibits scale & corrosion. Regular dosing of MAX - 100 can control further scale formations.

Biocides : MAX - 200 & MAX – 300

Algae and fungus are formed due to the exposure to sunlight of the cooling systems. This formation causes loss of heat transfer when it gets blocked in the water lines. These organisms escape into water tubes, pipelines and form a thin layer of slime which will have adverse affect on heat transfer. The rate of growth of algae increases in open cooling system, when compared to the closed systems. Further algae and fungus destroys the cooling systems as it blocks the spray nozzles which results in reduced flow of water. Our algae control chemical inhibits further algae formation.

Chemical control of biological growths involves killing or inhibiting the growth of these organisms. MAX - 200 & MAX - 300 are powerful biocides to arrest the growth of algae and fungi. It is also very effective against iron bacteria and thus prevents rusting. It can be administered in shock dosage to kill the growth of algae. It can also be used in lower concentrations to inhibit the growth of micro-organisms. Prevention of growth of algae & fungi results in improved efficiency of the cooling systems by reducing heat transfer losses.
Max 100-Antiscalant
 
Max 200-Biocides
 
Max 300-Biocides
 
Max 200-Biocides
     
Max 100-Antiscalant
 
Max 300-Biocides
 
MATERIAL SAFETY DATA SHEET
REVISION NUMBER : 03
REVISED DATE : 12.07.2011

BASIC INFORMATION
Product Shipping Name : MAX – 100 ANTISCALANTS
Chemical Name & Synonyms : Antiscalant to keep the scales in unsaturation form.
Reactivity : Slightly corrosive on all Metals, if exposed to chemical directly for more than a week continuously, Non reactive on Plastics, Rubber.

Product Description
Light pink coloured liquid, which is easily soluble in water. Ph : 2.0 – 3.0, Slightly corrosive on all Metals if exposed to chemical directly for more than a week continuously, Non reactive on Plastics, Rubber. To be dosed at PPM levels.

Manufacturer's Name & Address
Vendor : MAX CHEM CORPORATION
# 2701, 7th Main, H.A.L 3rd Stage
Jeevan Bhima Nagar
Bangalore – 560 075, Karnataka, India.

Contact Person / Numbers
Office : + 91 080 - 25294964( A.Sriinivasulu – Proprietor )
Cell : + 91 9741414429 ( A.Sriinivasulu – Proprietor )
Email : maxchem@in.com
Website : www.maxchem.in , www.descalingchemicals.in

PRINCIPAL INGREDIENTS
This chemical is used for suppressing the scale formation in cooling water lines. It controls the deposition of scales by not allowing the scales to precipitate. This chemical is a mixture of organic and inorganic compounds like H.E.D.P, Anti Corrosive Chemicals, Sodium Iodate, Ph Reducers, etc., This is only for your kind information and do not experiment on these details.

PHYSICAL & CHEMICAL PROPERTIES
Appearance & odor : Pale pink coloured liquid with light pungent smell
Solubility : Easily soluble in water
Chemical state : Acidic and Corrosive
Fire point : Nil
Flash point : Nil
Specific gravity : 1.01 - 1.02
pH : 2.0 - 3.0

REACTIVITY DATA
Stability : Stable
Conditions to avoid : Do not Inhale, Do not keep the cap loosely or opened
Materials to avoid : Do not spill anywhere, Should be directly dosed to cooling water lines.

Hazardous decomposition
This chemical should not come in contact with human body, especially with eyes, unhealed cuts, nose, skin etc., it should not be inhaled as it is concentrated with pungent smell. Please use goggles and hand gloves while handling. The cooling tower water should not be used for washing face or vessels, nor for bathing purposes and at the same time it can be used for watering plants.

FIRST AID PRECAUTIONS
Eyes / Skin / Unhealed Cuts : Flush with fresh and clean water thoroughly and immediately for 5 – 10 minutes. If there is still any kind of irritation, please take medical care immediately. Wear safety glasses as a safety and precautionary measure

Nose : Do not try to smell or inhale, as it is concentrated and very strong with pungent smell.
Spill on floors : Please wash with water immediately till the slippery feeling goes. A white patch will be left behind after it dries, which will gradually disappear over a period of time.

Swallowed : Give cold milk immediately and then take medical care at once.

Symptoms of exposure : Nothing serious. Wash with water thoroughly and take fresh air for 10 – 15 minutes. No need for Medical attention.
FIRE & EXPLOSION HAZARD DATA
Flammable limits : Non-flammable

HANDLING INFORMATION The material comes in plastic carbouys packing. The cap of the carbouys should be tightly closed after each use to avoid leakage and loss of concentration. The chemical should be used within a period of 6 months from the date of supply, for good results. The material should be stored at room temperature. However, the chemical does’nt ignite at high or low temperatures.

Waste disposal method
Unused chemical has to be sent to be ETP before disposal.

EXPOSURE CONTROLS & PERSONAL PROTECTION
Eye protection : Wear Goggles
Skin protection : Wear Hand Gloves
Ventilation recommended : Normal
Respiratory protection : Wear Nose Masks

Please note: The above mentioned information especially about the composition and chemical properties is approximate and their may be subsequent changes depending on the usage and the metal to which is comes in contact with. Do not try to experiment on the above information and we shall not be responsible for any such kind of acts and hazards arising out of it.

We request the consumers to review this information carefully before use and disposal.
 
 